Tuis > Produkte > AC komponente > AC isolator skakelaar > AC Elektriese Rotary Isolation Disconnect Switch
AC Elektriese Rotary Isolation Disconnect Switch
  • AC Elektriese Rotary Isolation Disconnect SwitchAC Elektriese Rotary Isolation Disconnect Switch
  • AC Elektriese Rotary Isolation Disconnect SwitchAC Elektriese Rotary Isolation Disconnect Switch
  • AC Elektriese Rotary Isolation Disconnect SwitchAC Elektriese Rotary Isolation Disconnect Switch
  • AC Elektriese Rotary Isolation Disconnect SwitchAC Elektriese Rotary Isolation Disconnect Switch
  • AC Elektriese Rotary Isolation Disconnect SwitchAC Elektriese Rotary Isolation Disconnect Switch
  • AC Elektriese Rotary Isolation Disconnect SwitchAC Elektriese Rotary Isolation Disconnect Switch

AC Elektriese Rotary Isolation Disconnect Switch

ADELS® is 'n gespesialiseerde vervaardiger en verskaffer in China van hoë gehalte AC elektriese roterende isolasie-ontkoppelskakelaar. AC Elektriese Rotary Isolation Disconnect Switch is ontwerp en vervaardig volgens GB/14048.3 en IEC60947-3, FM30 reeks las isolasie skakelaar word gebruik vir AC 50Hz, gegradeerde operasionele spanning tot 440V, nominale stroom tot 100A in elektriese stroombane, vir ventilasie toerusting, lugversorgers en waterpompe op die hoofskakelaar van die stelsel, kan ook klein-kapasiteit motor direk beheer. Bespreek vandag 'n konsultasie en kyk hoe ons skakelaars by jou markbehoeftes pas.

Model:FM30

Stuur navraag    PDF aflaai

Produk Beskrywing
ADELS

AC Elektriese Rotary Isolation Disconnect Switch


â¢Omgewingstemperatuur Moenie 40 °C oorskry nie, en die gemiddelde temperatuur, gemeet oor 'n tydperk van 24 uur, moenie 35°C oorskry nie;
â¢Omgewingstemperatuur moet nie onder -250°C wees nie;
â¢Moet nie meer as 2000m bo seevlak geïnstalleer word nie;
â¢Die hoogste temperatuur van 40°C, relatiewe humiditeit van lug nie meer as 50%. By laer temperature word 'n hoër humiditeit toegelaat, soos by 20°C, tot 90% humiditeit toegelaat. Dit sal die spesiale behandeling teen die kondensasiewater aanneem.



AC Electric Rotary Isolation Disconnect Switch inleiding


â¦FM30-reeks lasisolasieskakelaar word gebruik vir AC 50Hz, nominale operasionele spanning tot 440V, nominale stroom tot 100A in elektriese stroombane, vir ventilasie van toerusting, lugversorging en waterpompe op die hoofskakelaar van die stelsel, kan ook direk beheer klein-kapasiteit motor.
â¦Draaiskakelaars voldoen aan: GB/14048.3 en IEC60947-3.
.FM30-reeks skakelaarspesifikasies, 20A, 25A, 32A, 40A, 63A en 80A, 100A stroomgradering.
â¦FM30 reeks skakelaar het 'n klein grootte, kompakte struktuur, keuse van pragtige, goed geïsoleerde, met vinger funksie, veilig en betroubaar, jy kan ander by die 3-polige standaard blok kontakte voeg sonder om die skakelaar uitmekaar te haal.
â¦FM30-reeks skakelaar-isolasie-afstande groter as die ander skakelaar, ontkoppel die spoed, van toepassing op GS-skakeling.


Normale werksomstandighede


â¦Omgewingstemperatuur Moenie 40 °C oorskry nie, en die gemiddelde temperatuur, gemeet oor 'n tydperk van 24 uur, moet nie 35°C oorskry nie;
â¦Omgewingstemperatuur moet nie onder -250°C wees nie;
â¦Moet nie meer as 2000m bo seevlak geïnstalleer word nie;
â¦Die hoogste temperatuur van 40°C, relatiewe humiditeit van lug nie meer as 50%. By laer temperature word 'n hoër humiditeit toegelaat, soos by 20°C, tot 90% humiditeit toegelaat. Dit sal die spesiale behandeling teen die kondensasiewater aanneem.


Installasie voorwaardes


'n Skoon omgewing word vereis ï¼
Volg asseblief ons handleiding installasieï ¼


Klassifikasie


â¦Geklassifiseer volgens gebruik
â¦Geklassifiseer volgens beskermende vlak
(1) Sonder plastiek boks ¼ IP2L0
(2) Met plastiek boks ¼ IP65


Tegniese parameters


Tik

 

FM30-25

FM30-32

FM30-40

FM30-63

FM30-100

FM30-125

Gegradeerde termiese stroom (Ith)

A

25

32

40

63

100

125

Gegradeerde werkspanning (Ue)

V

240 440

240 440

240 440

240 440

240 440

240 440

Aanslagwaarde (le/kW)

             

AC-21A

A/kw

20/-20/-

32/-32/-

40/-40/-

63/-63-

100/-100/-

125/-125/-

AC-22A

A/kw

20/-20/-

32/-32/-

40/-40/-

63/-63-

100/-100/-

125/-125/-

AC-23A

VKW

15/4

15/7.5

22/5.5

22/11

30/7,5

30/7,5

43/11

43/22

70/22

70/22

 

AC-3

A/kw

11.7/3

11,7/5,5

15/4

15/7.5

22/7.5

22/11

36/11

36/18.5

57/18,5

57/30

 

Huidige tipe: AC 50Hz
Nommer van hoofkontak: AAN of AF
Frekwensie: 8 uur werk/intermitterende periodieke diens, /h bedryfsfrekwensie is 30 keer. Elektriese lewensduur: 10 000 keer / AC-23, 6 000 keer / AC-3, hulpkontakte vir 2000 keer.


Klassifikasie


FM30-reeks deurslot Gids Installasie D2(50/100/150/200)



Tik

Omlyn grootte

Montage grootte

A

LI

L

E

F

DI

D2

FM30-20

50

32

150

48

48

422

04.2
FM30-25

50

32

150

48

48

(D22

FM30-32

50

32

150

48

48

022

04.2
FM3040

61

32

150

48

48

022

0)4.2
FM30-63

61

32

150

48

48

(D4.2
FM30-80

68

32

150

48

48

(D22

(D4.2
FM30-100

68

32

150

48

48

022

04.2

Let wel: Produk kan in 35mm para la I geïnstalleer word


AC Isolator Seleksie - AC Elektriese Rotary Isolation Disconnect Switch


⦠AC-isolators word in beide alleenstaande rooster- of netwerkverspreide stelsels gebruik. As dit aan die verspreide netwerk gekoppel is, bepaal G83/1 dat die FV-stelsel direk aan 'n isolasieskakelaar gekoppel moet word wat bedraad is om beide die lewendige en neutrale geleiers te isoleer, wat in die âOFFâ posisie vasgemaak kan word en op 'n toeganklike plek binne die installasie.
â¦Anders as 'n GS-isolator wat nodig is om beide die positiewe en negatiewe geleiers te skakel, moet 'n AC-isolator gekies word met betrekking tot die toevoer wat enkelfase is, wat tipies in huishoudelike installasies of driefase aangetref word, wat tipies is vir kommersiële of industriële installasies. Ideaal gesproke vir enkelfase moet 'n 2-polige isolator gebruik word om die lewendige en neutrale lyn (aarde voortdurend verbind) te skakel, terwyl 'n 4 pool isolator gebruik sal word om die 3 spanningslyne en neutraal (aarde voortdurend verbind) te skakel.
â¦Die isolatorgradering moet gebaseer wees op die omskakelaaruitset wat normaalweg per fase gespesifiseer word, dit is lyn na neutraal, en byvoorbeeld as 20A by 230VAC getoon word; as hierdie uitset van 'n driefase-eenheid is, moet die AC-isolator gegradeer word vir die lyn-tot-lyn spanning wat tipies 415VAC sal wees.
â¦Met beide AC- en DC-isolators moet die omgewingstemperatuur van die omgewing waarin die skakelaar gemonteer is, in ag geneem word aangesien die meeste industriële skakelaars nominaal gegradeer is vir gebruik in 35°C. As die isolator egter gebruik gaan word in 'n area waar sonaktiwiteit algemeen voorkom, en sodoende die installasie meer doeltreffend gebruik en groter opbrengs, of in 'n geslote ruimte soos 'n hok of dié van 'n omskakelaar-omhulsel, dan kan 'n isolator van die hantering van die verhoogde temperature moet gekies word.



Hot Tags: AC Elektriese Rotary Isolation Disconnect Switch, China, vervaardigers, verskaffers, fabriek, pasgemaak, handelsmerke, pryslys, kwotasie, CE, kwaliteit
Verwante kategorie
Stuur navraag
Voel asseblief vry om jou navraag in die vorm hieronder te gee. Ons sal jou binne 24 uur antwoord.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept